XPS Unified Programmer’s Manual
Input parameters
SocketID int Socket identifier gets by the
“TCP_ConnectToServer” function.
PositonAbsoluteX_um double Target position in µm for X axis.
PositonAbsoluteY_um double Target position in µm for Y axis.
Output parameters
None.
Return (In addition to the results of “Input Tests Common to all XPS
Functions”)
0: No error.
-8: Wrong object type for this command.
-17: Parameter out of range or incorrect.
-18: Positioner Name doesn't exist or unknown command.
-19: GroupName doesn't exist or unknown command.
-22: Not allowed action.
-25: Following Error.
-26: Kill command or Emergency signal: check each positioners and each
slave positioners, check that motion does not exceed software limits
when combined with mapping and other features.
-27: Move Aborted.
-33: Motion done timeout.
-44: Slave error disabling master.
-120: Warning following error during move with position compare enabled.
EDH0373En1023 01/18 614