Solution System 337Service Manual – CS7000
13. Remove the ve mounting screws holding the solution tank to the frame. The mounting screw locations
are shown below.
The three bottom mounting screws
are located underneath the machine
- two on the right side and one in
the center of the frame. The two top
mounting screws are located on the
vertical supports on the left side of
the machine where the main machine
controller is mounted.
The two top Solution Tank Mounting Screws are
located on the vertical supports on the left
side of the machine.
The bottom rear Solution Tank Mounting Screw is
located underneath the machine on the right side by
the solution shutoff valve and drain hose.
Solution Tank
Mounting Screw
Locations
=
Solution Tank
Mounting Screw
Solution Tank
Mounting Screw
Solution Tank
Mounting Screw