LP Configuration
206 A29247-X6-X-6-7670
exit Exit lpc interactive mode
help Display help text
quit End lpc interactive mode
start {all | [printer ...]} Enable printing on all or the specified printer
status {full} {[printer]} Display short or full status information for all or
the specified printer
stop {all | [printer ...]} Stop printing on all printer or the specified
printer
topq [printer] [jobnum ...] [user ...] Push the specified job(s) to the front
of the print queue
up {all | [printer ...]} Enable queuing and printing on all or the spe-
cified printers
? Display help text
Supported options for subcommands:
printer name
job id
Examples:
lpc status full PS700_1
This displays the full status information for the specified printer PS700_1.
Server2->PS700_1:
Queuing is enabled
Printing is enabled
Number of jobs in local queue: 0
Number of jobs in PRISMA queue: 5
Example for interactive mode:
lpc
lpc>help
Commands can be abbreviated. Commands are:
abort enable disable help restart status topq ?
clean exit down quit start stop up
lpc>topq PS700_1 jobnum 00000815
lpc>quit