Chapter2 Setting Recovery
System Operation and Functions
E
2-26. Setting Recovery
The Setting Recovery function configurable with the Configuration Tool may increase risks. Make
sure the Responsible Person conduct a thorough risk assessment analysis before managing and
changing the settings. Unintended changes to the settings may cause a person to go
undetected, resulting in serious injury.
2-26-1. Overview
You can use the Configuration Tool to recover the F3SG-RA setting to the default factory setting.
Make sure the Position 8 of the DIP Switch is set to Configuration Tool Enabled to activate the settings by the
Configuration Tool.
Refer to Safety Light Curtain Configuration Tool for Model F3SG (SD Manager 2) User’s Manual for more
information on setting this function by the Configuration Tool.
The Setting Recovery is not available for the F3SG-RE.
F3SG-RA Series X
F3SG-RE Series

Table of Contents

Other manuals for Omron F3SG series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron F3SG series and is the answer not in the manual?

Omron F3SG series Specifications

General IconGeneral
TypeSafety Light Curtain
Protection RatingIP67
ConnectionM12 connector
Detection MethodInfrared Light
Operating Temperature-10°C to +55°C
Resolution14mm, 25mm, 40mm
StandardsEN/IEC 61496-1, EN ISO 13849-1
Power Supply Voltage24V DC ±10%

Related product manuals