Chapter6 Pre-Operation Checklists
F3SG-R
User’s Manual
Checklists
When the ON/OFF indicator is green and the F3SG-RA is blocked and then returned to unblocked
state, the ON/OFF indicator remains red. The RESET input turns the ON/OFF indicator to green.
When muting function is used, minimum muting time limit required must be set.
When muting function's operation mode is exit-only muting mode, minimum muting end wait time
required must be set.
Under muting state, a signal that indicates muting state must be output from the Auxiliary Output.
When override function is used, minimum override time limit required must be set.
Under override state, a signal that indicates override state must be output from the Auxiliary Output.
6-1-1-4. Checking that Hazardous Parts Stop While the Machine Operates
The hazardous parts stop immediately when a test rod is inserted into the detection zone at 3
positions: "directly in front of the emitter", "directly in front of the receiver", and "between the emitter
and receiver". (Use the appropriate test rod.)
The hazardous parts remain stopped as long as the test rod is in the detection zone.
The hazardous parts stop when the power of the F3SG-R is turned OFF.
The actual response time of the whole machine is equal to or less than the calculated value.

Table of Contents

Other manuals for Omron F3SG series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron F3SG series and is the answer not in the manual?

Omron F3SG series Specifications

General IconGeneral
TypeSafety Light Curtain
Protection RatingIP67
ConnectionM12 connector
Detection MethodInfrared Light
Operating Temperature-10°C to +55°C
Resolution14mm, 25mm, 40mm
StandardsEN/IEC 61496-1, EN ISO 13849-1
Power Supply Voltage24V DC ±10%

Related product manuals