36
Chapter2 Interlock
F3SG-R
User’s Manual
System Operation and Functions
• Pre-Reset mode
2-9-2. Factory Default Setting
The factory default setting is Auto Reset mode enabled, Start Interlock, Restart Interlock and Pre-
Reset mode disabled.
2-9-3. Setting with DIP Switch
The user can select the mode from Auto Reset, Manual Reset or Pre-Reset by the DIP Switch.
When configured to Manual Reset mode, the Start Interlock and Restart Interlock are enabled.
When configured to Pre-Reset mode, the function is activated with the following conditions:
• Maximum number of times the F3SG-RA is blocked after input of PRE-RESET signal: Infinite (The
F3SG-RA must be blocked at least once.)
• Maximum period of time from input of PRE-RESET signal to input of RESET signal: 8 s
Make sure the Position 8 of the DIP Switch is set to DIP Switch Enabled to activate the settings by the DIP Switch.
Refer to Chapter 3 Setting with DIP Switch for more information on setting this function by the DIP Switch.
T1 T1
T2 T2
T3 T3
Pre Reset SW
Beam state
Reset SW
OSSD
ON
OFF
Unblocked
Blocked
ON
OFF
ON
OFF
Auxiliary Output *
ON
OFF
INT-LK Indicator
ON
OFF
Flash
once
Flash
twice
Solid
on
T1: Push time: must be T1 >= 300 ms
T3: Push time: must be T3 >= 300 ms
* When Auxiliary Output is set to Pre-Reset Enabled by the Configuration Tool.
T2: Pre-reset limit time between Pre-reset and Reset:
must be T2 <= 8 s (Factory default setting)