7
F3SG-R
User’s Manual
Chapter1 List of Features
Overview and Specifications
E
1-3-3. List of Features
The F3SG-R safety light curtain family has the following features. For the F3SG-RA, some of the
features are available or configurable by the DIP Switch on the body of the safety light curtain or the
Configuration Tool (SD Manager 2) via a PC.
Setting with DIP Switch and Configuration Tool is not available for the F3SG-RE.
* The functions are upgraded in Version 1.1 of F3SG-RA.
Functions by versions
Refer to 1-3-2. Versions to check versions of your F3SG-R.
Feature
F3SG-RA Series
F3SG-RE
Series
Page
Setting by
DIP Switch
Setting by
Configuration
Tool
Factory default setting
Scan Code Selection X Code A p.26
PNP/NPN Selection X PNP output p.27
External Test X 24 V Active p.30
Interlock X X Auto Reset Mode p.33
Pre-Reset X X Disabled p.38
External Device Monitoring(EDM) X X Disabled p.38
Auxiliary Output X Muting/Override information p.41
Muting X Standard Muting mode p.45
Override X Enabled p.71
Fixed Blanking * X X Disabled p.76
Floating Blanking * X X Disabled p.80
Reduced Resolution X Disabled p.85
Warning Zone X Disabled p.87
Operating Range Selection X Short mode X p.93
Response Time Adjustment X Normal mode p.95
Lamp
X
Red:Disabled
Orange:Disabled
Green:Muting/Override
information
p.96
Designated Beam Output X Disabled p.99
Muting Statistics Data Recording * X Enabled p.103
F3SG-R Version
1.0 1.1
Fixed Blanking Configuring an allowable beam is possible on
both ends of Fixed Blanking zone.
Configuring an allowable beam is possible on
both or either end of Fixed Blanking zone.
Floating Blanking Temporarily Disable Monitoring function is only
available when the F3SG-RA is in one
segment system.
Temporarily Disable Monitoring function is
available when the F3SG-RA is in either one
segment system or cascade connection.
Muting Statistics Information Monitoring muting statistics information is only
possible when it is offline.
Monitoring muting statistics information is
possible when it is either online or offline.
Clearing log files of muting statistics
information is possible.

Table of Contents

Other manuals for Omron F3SG series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron F3SG series and is the answer not in the manual?

Omron F3SG series Specifications

General IconGeneral
TypeSafety Light Curtain
Protection RatingIP67
ConnectionM12 connector
Detection MethodInfrared Light
Operating Temperature-10°C to +55°C
Resolution14mm, 25mm, 40mm
StandardsEN/IEC 61496-1, EN ISO 13849-1
Power Supply Voltage24V DC ±10%