Chapter3 DIP Switch
Setting with DIP Switch
E
according to the settings of the DIP Switch. When the Position 8 is switched back to ON, the F3SG-RA
operates according to the settings stored in the internal memory.
Note that Scan Code and PNP/NPN Selection are not affected by the Position 8 but by the DIP Switch
setting.
3-2-2. DIP Switch on Emitter
The following functional settings are available by DIP Switches on the emitter. For functional details,
see respective chapter in the Functional Details column.
: Indicates a switch position.
If the power is turned on while the switch is configured as Setting Inhibited, F3SG-RA transitions to lockout.
3-2-3. Push Switch
The F3SG-RA has a Push Switch between the two DIP Switches on the receiver. There is no Push
Switch on the emitter. The Push Switch is used to make the settings to the Fixed Blanking and Floating
Blanking by the Teach-in.
Refer to 3-3. Setting by Teach-in for more information.
Position Function Setting Description
Functional
Details
1 Scan Code
Scan Code A (factory default
setting)
2-4
Scan Code B
2-4
2, 3
Operating Range
Selection
Short Mode (factory default setting)
2-21
Setting Inhibited
-
Setting Inhibited
-
Long Mode
2-21
4 External Test
24 V Active (factory default setting)
2-7
0 V Active
2-7