EasyManuals Logo

Omron F3SG series User Manual

Omron F3SG series
257 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #13 background imageLoading...
Page #13 background image
xi
F3SG-R
User’s Manual
Introduction
E
Make sure to observe the following precautions that are necessary for ensuring safe use of the product.
Do not install, use, or store the F3SG-R in the following types of environments:
- Areas exposed to intense interference light, such as direct sunlight
- Areas with high humidity where condensation is likely to occur
- Areas where oil mist or corrosive gases are present
- Areas exposed to vibration or shock levels higher than in the specification provisions
- Areas where the product may come into contact with water
- Areas where the pollution degree is harsher than 3, such as outdoor environment
- Areas where the product may get wet with oil that can solve adhesive
Loads must satisfy both of the following conditions:
- Not short-circuited
- Not used with a current that is higher than the rating
Do not drop the product.
Dispose of the product in accordance with the relevant rules and regulations of the country or area where the
product is used.
Make sure that the F3SG-R is securely mounted and its cables and connectors are properly secured based
on the torque recommended in this document.
Bending radii of cables must be equal to or higher than specified minimum values.
When replacing the cable connectors with other types of connectors, use connectors that provide a
protection grade of IP54 or higher.
Be sure to route the input/output lines for the F3SG-R separate from high-potential power lines or through an
exclusive conduit.
To extend a cable length with a cable other than the dedicated cable, use a cable with the same or superior
specifictions.
Refer to 4-5-3-4. Extending Cable Length with Commercially Available Cable
In environments where foreign material such as spatter adheres to the F3SG-R, attach a cover to protect the
F3SG-R from the spatter.
Interface Unit F39-GIF is dedicated to the F3SG-R series. Do not use it for F3SJ-A or F3SJ-E/B series.
Read and understand this document for DIP Switch setting.
The rated life of this product is 6 years.
Precautions for Safe Use

Table of Contents

Other manuals for Omron F3SG series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron F3SG series and is the answer not in the manual?

Omron F3SG series Specifications

General IconGeneral
TypeSafety Light Curtain
Protection RatingIP67
ConnectionM12 connector
Detection MethodInfrared Light
Operating Temperature-10°C to +55°C
Resolution14mm, 25mm, 40mm
StandardsEN/IEC 61496-1, EN ISO 13849-1
Power Supply Voltage24V DC ±10%