9 - 71
9 Details on Servo Parameters
AC Servomotors/Servo Drives 1S-series with Built-in EtherCAT® Communications User’s Manual (I586)
9-7 Applied Function Objects
9
9-7-7 3B40 hex: Zone Notification 1
Gives the position which is latched on the positive edge by the Latch Function 2 (Touch Probe 2).
Mirror object of 60BC hex
Sets the Latch Function 2.
Description of Set Values
Sets the Zone Notification 1.
Sets the lower limit range of Zone Notification.
Sets the upper limit range of Zone Notification.
Subindex 84 hex: Touch Probe 2 Positive Edge
Subindex F1 hex: Setting
Set value Description
Bit 8 Enable or disable Latch Function 2
0 Disabled
1 Enabled
Bit 9 Latch 2 operation
0 Latch on the first trigger only.
1 Latch continuously on every trigger input
Bit 10 and 11 Latch 2 trigger input signal switch
00 EXT2
01 Phase Z
10 Follow the setting in the Touch probe source.
11 Reserved
Bit 12 Latch 2 trigger operation on the positive edge
0 Latch is disabled
1 Latch is enabled
9-7-7 3B40 hex: Zone Notification 1
Index
(hex)
Sub-
index
(hex)
Object name Setting range Unit
Default
setting
Data
attri-
bute
Size Access
PDO
map
Complete
access
Modes
of opera-
tion
3B40 --- Zone Notification
1
--- --- --- --- --- --- --- Possible ---
00 Number of
entries
--- --- 81 hex --- 1 byte
(U8)
RO --- --- ---
01 Lower Limit -2,147,483,648
to
2,147,483,647
Com-
mand
unit
0 A 4 bytes
(INT32)
RW --- --- ---
02 Upper Limit -2,147,483,648
to
2,147,483,647
Com-
mand
unit
0 A 4 bytes
(INT32)
RW --- --- ---
81 Status --- --- --- --- 4 bytes
(INT32)
RO --- --- ---
Subindex 01 hex: Lower Limit
Subindex 02 hex: Upper Limit

Table of Contents

Other manuals for Omron R88D-1SN ECT Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron R88D-1SN ECT Series and is the answer not in the manual?

Omron R88D-1SN ECT Series Specifications

General IconGeneral
FeedbackIncremental encoder, Absolute encoder
Position ControlYes
Speed ControlYes
Torque ControlYes
Communication InterfaceEtherCAT
Power Supply Voltage200 to 240 VAC
Output Power0.1 to 1.5 kW
Input Voltage Range170 to 264 VAC
Control MethodSine-wave PWM control
Main Circuit Power Supply200-240 VAC
Applicable Motor Capacity0.1 to 1.5 kW
Protection FunctionsOvercurrent, Overvoltage, Undervoltage, Overheating, Encoder Error
Ambient Operating Temperature0 to 55°C
Vibration Resistance4.9 m/s² (10 to 55 Hz)
Shock Resistance98 m/s2
WeightVaries by model