15-34
FP0R (A: Available, N/A: Not available)
Address Name Description
DT90300
Elapsed
value
area
Lower words
HSC-CH0
Counting area for input (X0) or
(X0, X1) of the main unit.
A A
Note)
DT90301 Higher words A A
Note)
DT90302
Target
value
area
Lower words
The target value is set when
instructions F166 (HC1S) and
F167 (HC1R) are executed.
A A
Note)
DT90303 Higher words A A
Note)
DT90304
Elapsed
value
area
Lower words
HSC-CH1
Counting area for input (X1) of
the main unit.
A A
Note)
DT90305 Higher words A A
Note)
DT90306
Target
value
area
Lower words
The target value is set when
instructions F166 (HC1S) and
F167 (HC1R) are executed.
A A
Note)
DT90307 Higher words A A
Note)
DT90308
Elapsed
value
area
Lower words
HSC-CH2
Counting area for input (X2) or
(X2, X3) of the main unit.
A A
Note)
DT90309 Higher words A A
Note)
DT90310
Target
value
area
Lower words
The target value is set when
instructions F166 (HC1S) and
F167 (HC1R) are executed.
A A
Note)
DT90311 Higher words A A
Note)
DT90312
Elapsed
value
area
Lower words
HSC-CH3
Counting area for input (X3) of
the main unit.
A A
Note)
DT90313 Higher words A A
Note)
DT90314
Target
value
area
Lower words
The target value is set when
instructions F166 (HC1S) and
F167 (HC1R) are executed.
A A
Note)
DT90315 Higher words A A
Note)
DT90316
Elapsed
value
area
Lower words
HSC-CH4
Counting area for input (X4) or
(X4, X5) of the main unit.
A A
Note)
DT90317 Higher words A A
Note)
DT90318
Target
value
area
Lower words
The target value is set when
instructions F166 (HC1S) and
F167 (HC1R) are executed.
A A
Note)
DT90319 Higher words A A
Note)
Note) Writing in the elapsed value area is available by F1 (DMV) instruction only.
Writing in the target value area is available by F166 (HC1S) and F167 (HC1R) instructions only.