8-39
Sample program
Control code
Precautions during programming
- For using the pulse output function, it is necessary to set the system register No. 402.
- Performing rewriting during RUN stops the pulse output.
- When the deceleration stop is requested by the F0 instruction during the pulse output, the deceleration
stop is performed.
- When the instruction is started during the interrupt program, specify the execution in the interrupt
program with the control code. When describing the same channel in both the normal program and the
interrupt program, be sure to program not to execute them simultaneously.