Scalar DLC Reference Guide 95
If the cartridge is not found in the library after the Inventory has been executed, its state changes to offline.
After that, the cartridge is removed from the cartridge list of the Logical library and goes to archive list, or
the list of the offline cartridges. It is shown under the Physical tab and contains the information about
cartridges that were removed from the physical library. Refer to Offline Cartridge
on page 121.
Field/Button Icon Operation Description
Name Supplied Name (volser), stable for a normal cartridge.
Enter Name (volser), editable for a foreign cartridge.
Also refer to Table 6
on page 16.
ID Supplied Cartridge identification number.
Assigned drive Select A drive assigned to cartridge, if any. If the Generic
mount operation is executed, the cartridge loads into
the assigned drive if it is available.
Type Select Cartridge type (data/clean)
Current slot Supplied The slot where the cartridge is right now.
Previous slot Supplied The slot where the cartridge was previously.
Home slot Supplied The cartridge home position. Refer to Home Position
on page 79.
State Select Cartridge state. See Table 19
on page 78 for the
details.
Status Supplied The cartridge availability for the commands.
Owner Supplied The cartridge owner (client), if any.
Media type Supplied Media type, stable for a normal cartridge. Refer to
Media Type
s on page 246.
Select Media type, changeable for a foreign cartridge. Refer
to Media Type
s on page 246.
Use count Supplied Number of mounts performed (for the data cartridge
only).
Number of cleanings
done
Supplied Number of cleanings performed (for the cleaning
cartridge only).
Update Click Save the cartridge properties after edit.
Reset Alarm flag Click Remove Alarm flag (active only when the cartridge is
in Alarm state).
Refresh Alarm flag Click Refresh Management GUI for Alarm.
Help Click Open online help for the current pane.