EasyManuals Logo
Home>Quantum>Storage>Scalar 1000

Quantum Scalar 1000 Reference Guide

Quantum Scalar 1000
304 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #32 background imageLoading...
Page #32 background image
16 Configuration
Configuration
When a user is logged into the Management GUI and no previously configured physical library has been
found, a configuration selection pane opens automatically (see Figure 10
); if the configuration has been
performed, this pane will not appear. Choose the configuration method.
Figure 10 Configuration Window
Either accept the default configuration or select the desired configuration method.
A
utomatic Configuration on page 17 is recommended for the first-time users that have no
experience in configuring the Scalar DLC system.
Wizard-based Manual Configuration
on page 18 is recommended for the users with basic
knowledge about the configuration of the Scalar DLC.
Advanced Configuration
on page 18 is designed for the advanced users that have enough
experience to perform all configuration manually.
After the basic configuration is finished, an Additional Configuration
on page 23 could be performed.
Some client interfaces have certain limitations concerning the names of used objects, for example, some
DAS-based applications do not recognize the mailbox name for Insert command other than Ixx (xx means
any two alphanumeric characters). To avoid such issues, be sure that the objects created and configured
by means of the Scalar DLC Management GUI are named as shown in the Table 6
.
Note
Some customer (client) applications do understand the capitalization difference (A and
a), the others do not. ADIC recommends using the common alpha-model (either capitals
or small letters in all object names).
ADIC also strongly does not
recommend using spaces (“ “), underscores (“_”), hyphens
(“-”) and other symbols in the object names. Even when the Scalar DLC Management
GUI permits this, the client application may not recognize the appropriate object.
Table 6 Object name limitations
Object GUI Manager DAS / ACI ROBAR SCSI
Host 40 an
a
, a first 40 an, a first An None
Logical library 30 an, a first None (absent) None
(absent)
None

Table of Contents

Other manuals for Quantum Scalar 1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Quantum Scalar 1000 and is the answer not in the manual?

Quantum Scalar 1000 Specifications

General IconGeneral
BrandQuantum
ModelScalar 1000
CategoryStorage
LanguageEnglish

Related product manuals