EasyManua.ls Logo

R&S FSV3000 Series - Page 1106

R&S FSV3000 Series
1268 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote Commands
R&S
®
FSVA3000/ R&S
®
FSV3000
1106User Manual 1178.8520.02 ─ 01
[SENSe:]CORRection:FRESponse:BASeband:USER:FLISt<fli>:PHASe[:STATe]
<State>
[SENSe:]CORRection:FRESponse:INPut<ip>:USER:FLISt<fli>:PHASe[:STATe]
<State>
[SENSe:]CORRection:FRESponse:USER:FLISt<fli>:PHASe[:STATe] <State>
Activates or deactivates the use of the correction data in the selected file for magnitude
results.
Suffix:
<fli>
.
1..n
Index in frequency response file list
Use [SENSe:]CORRection:FRESponse:BASeband:USER:
FLISt<fli>:SIZE? to determine the maximum index number.
Parameters:
<State> ON | OFF | 0 | 1
OFF | 0
Applies the data for magnitude results.
ON | 1
Does not apply the data for magnitude results.
*RST: 1
Example:
SENS:CORR:FRES:USER:FLIS2:PHAS:STAT ON
Manual operation: See "Phase" on page 611
[SENSe:]CORRection:FRESponse:BASeband:USER:FLISt<fi>:REMove
[SENSe:]CORRection:FRESponse:INPut<ip>:USER:FLISt<fli>:REMove
[SENSe:]CORRection:FRESponse:USER:FLISt<fli>:REMove
Removes the selected frequency response (.fres) file from the current configuration.
Suffix:
<fli>
.
1..n
Index in frequency response file list
Use [SENSe:]CORRection:FRESponse:BASeband:USER:
FLISt<fli>:SIZE? to determine the maximum index number.
Example:
SENS:CORR:FRES:USER:FLIS2:REM
Usage: Event
Manual operation: See "Remove Frequency Response File" on page 611
[SENSe:]CORRection:FRESponse:BASeband:USER:FLISt<fli>:SELect <FilePath>
[SENSe:]CORRection:FRESponse:INPut<ip>:USER:FLISt<fli>:SELect <FilePath>
[SENSe:]CORRection:FRESponse:USER:FLISt<fli>:SELect <FilePath>
Loads an additional frequency response (.fres) file to the current configuration.
Configuring the R&S
FSV/A