Remote Commands
R&S
®
FSVA3000/ R&S
®
FSV3000
1111User Manual 1178.8520.02 ─ 01
[SENSe:]CORRection:FRESponse:BASeband:USER:SLISt<sli>:MOVE <Direction>
[SENSe:]CORRection:FRESponse:INPut<ip>:USER:SLISt<sli>:MOVE <Direction>
[SENSe:]CORRection:FRESponse:USER:SLISt<sli>:MOVE <Direction>
Moves the selected Touchstone file one position up or down in the list of files, changing
the order in which the correction data is applied.
Suffix:
<sli>
.
1..n
Index in Touchstone file list
Use [SENSe:]CORRection:FRESponse:USER:
SLISt<sli>:SIZE? to determine the maximum index number.
If an index outside the available range is specified, an error
occurs.
Setting parameters:
<Direction> UP | DOWN
Example:
SENS:CORR:FRES:USER:SLIS:MOVE UP
Usage: Setting only
Manual operation: See "Move File Up or Down" on page 610
[SENSe:]CORRection:FRESponse:BASeband:USER:SLISt<sli>:PORTs:FROM
<PortFrom>
[SENSe:]CORRection:FRESponse:INPut<ip>:USER:SLISt<sli>:PORTs:FROM
<PortFrom>
[SENSe:]CORRection:FRESponse:USER:SLISt<sli>:PORTs:FROM <PortFrom>
SnP files can be defined for a varying number of input and output ports.
You must define the ports from the touchstone file whose data is to be applied.
Suffix:
<sli>
.
1..n
Index in Touchstone file list
Use [SENSe:]CORRection:FRESponse:USER:
SLISt<sli>:SIZE? to determine the maximum index number.
Parameters:
<PortFrom> *RST: 1
Example:
SENS:CORR:FRES:USER:SLIS:SEL 'FRes21.s2p'
SENS:CORR:FRES:USER:SLIS:PORT:TO 2
SENS:CORR:FRES:USER:SLIS:PORT:FROM 1
The correction data from port 1 to port 2 is included in the filter.
Manual operation: See "To - From" on page 609
Configuring the R&S FSV/A