Remote Commands
R&S
®
FSVA3000/ R&S
®
FSV3000
771User Manual 1178.8520.02 ─ 01
Suffix:
<sb>
.
1..n
sub block number
<ch> 1..n
Tx channel number
Parameters:
<Standard> GSM | WCDMa | LTE_1_40 | LTE_3_00 | LTE_5_00 |
LTE_10_00 | LTE_15_00 | LTE_20_00 | USER
Technology used for transmission
GSM
Transmission according to GSM standard
WCDMa
Transmission according to W-CDMA standard
LTE_1_40 | LTE_3_00 | LTE_5_00 | LTE_10_00 | LTE_15_00 |
LTE_20_00
Transmission according to LTE standard for different channel
bandwidths
USER
User-defined transmission; no automatic preconfiguration possi-
ble
Manual operation:
See " Technology Used for Transmission " on page 174
[SENSe:]POWer:ACHannel:SBLock<sb>:TXCHannel:COUNt <Number>
This command defines the number of transmission channels the specific sub block
contains.
This command is for MSR signals only (see CALCulate<n>:MARKer<m>:
FUNCtion:POWer<sb>:PRESet on page 752).
Suffix:
<sb>
.
1..n
sub block number
Parameters:
<Number> Range: 1 to 18
*RST: 1
Manual operation: See " Number of Tx Channels ( Tx Count )" on page 173
[SENSe:]POWer:ACHannel:SPACing:UACHannel <Spacing>
This command defines the distance from the transmission channel to the upper adja-
cent channel.
For MSR signals, this command defines the distance from the CF of the last Tx chan-
nel in the last sub block to the upper adjacent channel in asymmetrical configurations.
To configure the spacing for the lower adjacent channel use the [SENSe:]POWer:
ACHannel:SPACing[:ACHannel] command.
Configuring and Performing Measurements