Remote Commands
R&S
®
FSVA3000/ R&S
®
FSV3000
906User Manual 1178.8520.02 ─ 01
Suffix:
<n>
.
Window
<t> irrelevant
Manual operation: See " Auto Scale Once " on page 375
DISPlay[:WINDow<n>][:SUBWindow<w>]:TRACe<t>:Y[:SCALe]:MODE <arg0>
This command selects the type of scaling of the y-axis (for all traces).
When the display update during remote control is off, this command has no immediate
effect.
Suffix:
<n>
.
Window
<w> subwindow
<t> irrelevant
Parameters:
<arg0> ABSolute
absolute scaling of the y-axis
RELative
relative scaling of the y-axis
*RST: ABSolute
Example:
DISP:TRAC:Y:MODE REL
Manual operation: See " Scaling " on page 375
DISPlay[:WINDow<n>]:TRACe<t>:Y[:SCALe]:PDIVision <Value>
This remote command determines the grid spacing on the Y-axis for all diagrams,
where possible.
In spectrum displays, for example, this command is not available.
Suffix:
<n>
.
Window
<t> irrelevant
Parameters:
<Value> numeric value WITHOUT UNIT (unit according to the result dis-
play)
Defines the range per division (total range = 10*<Value>)
*RST: depends on the result display
Default unit: DBM
Example:
DISP:TRAC:Y:PDIV 10
Sets the grid spacing to 10 units (e.g. dB) per division