Remote Control Commands
R&S
®
SMB100A
377Operating Manual 1407.0806.32 ─ 21
[:SOURce]:POWer:WIGNore...........................................................................................381
[:SOURce<hw>]:POWer:LMODe..................................................................................... 381
[:SOURce<hw>]:POWer:MANual.....................................................................................382
[:SOURce<hw>]:POWer:MODE.......................................................................................382
[:SOURce<hw>]:POWer:POWer......................................................................................383
[:SOURce<hw>]:POWer:SPC:CRANge............................................................................ 383
[:SOURce<hw>]:POWer:SPC:DELay............................................................................... 384
[:SOURce<hw>]:POWer:SPC:PEAK................................................................................ 384
[:SOURce<hw>]:POWer:SPC:SELect.............................................................................. 384
[:SOURce<hw>]:POWer:SPC:STATe...............................................................................385
[:SOURce<hw>]:POWer:SPC:TARGet............................................................................. 385
[:SOURce<hw>]:POWer:STARt.......................................................................................385
[:SOURce<hw>]:POWer:STEP[:INCRement].................................................................... 386
[:SOURce<hw>]:POWer:STEP:MODE............................................................................. 386
[:SOURce<hw>]:POWer:STOP........................................................................................387
[:SOURce<hw>]:POWer:ALC:OMODe <OffMode>
The command sets the level control mode which becomes active when automatic level
control is deactivated (ALC Off).
Parameters:
<OffMode> SHOLd
SHOLd
Level control is activated briefly if the level or frequency changes
("ALC Off Sample & Hold").
*RST: SHOLd
Example:
POW:ALC OFF
deactivates automatic level control for RF output A.
POW:ALC:OMOD SHOL
level control is briefly activated if the frequency or level changes.
[:SOURce<hw>]:POWer:ALC:SONCe
Temporarily activates level control for correction purposes.
Example:
POW:ALC OFF
deactivates automatic level control for RF output A.
POW:ALC:SONC
level control is performed once only.
Usage: Event
Manual operation: See "Search Once - ALC" on page 153
[:SOURce<hw>]:POWer:ALC[:STATe] <State>
Activates/deactivates automatic level control.
SOURce Subsystem