Duplex Unit
SM 4-79 D062/D063/D065/D066
Replacement
and
Adjustment
Duplex Transport Sensor 3
1. Right half of table [A] ( x 2, x 1)
The front screw is a shoulder screw. Insert the screws in the correct holes when
re-attaching.
2. Remove the screw [B] to release the sensor bracket below.
3. Transport sensor 3 [C] (
x 1)
Inverter Exit Sensor, Transport Sensors 1 & 2
1. Cross-stay [A] (
x 4)
2. Reverse trigger roller shaft [B]