Service Call Conditions
SM Appendix 3-31 D062/D063/D065/D066
Appendix:
Service Call
Conditions
trays, an ACK signal is not
received within 100 ms, and is
not received after 3 retries.
External noise on the line
625 B
BCU/Finisher communication / timeout error
After 1 data frame is sent to the
Finisher MBX, and an ACK signal
is not received within 100ms, and
is not received after 3 retries.
Serial line connection unstable –
Finisher interface cable
External noise on the line
Finisher main board
BCU
626 D
BICU, LCT communication/timeout error
After 1 data frame is sent to the
LCT, an ACK signal is not
received within 100 ms, and is
not received after 3 retries.
Serial line connection unstable
External noise on the line
627 D
BICU, LCT communication/break reception error
During communication with the
LCT, the BICU received a break
(Low) signal.
Serial line connection unstable
External noise on the line
Rev. 03/12/2010