Service Program Mode Tables
D062/D063/D065/D066 4-40 SM Appendix
and LD power when the fusing temperature is lower than 100°C at power-on.
[0 to 1/1/1]
0: Off
1: On
This setting attempts to change the Vd setting consistent with the OPC, the
charge corona unit, and environment to improve the reliability of the system.
3902* Drum Condition Display
001 Auto Process Control On/Off
Displays whether auto process control is switched on or off (0:Off, 1:On)
When auto processing control is turned on, displays only when the potential
sensor is calibrated correctly. Auto process control is not executed when this SP
is switched off.
[0 to 1/1/1]
0: Off
1: On
002 Vd
Displays drum dark potential, the standard potential, electrical potential of the
black areas after exposure.
[100 to 970/800/1]
003 Vh
Displays standard halftone drum potential, used for laser power adjustment.
[100 to 500/300/1]
004 Vg
Displays the charge grid voltage resulting from the latest Vd adjustment.
[0 to 0xFFFF/0/0]
005 LD Level
Displays the LD power correction value as a result of the latest Vh adjustment.
[-127 to 127/0/0]