SC500: Feed, Transport, Duplex, and Fusing
D131/D132/D133 2-32 SM Appendix
SC544 A
Fusing lamp overheat error 1: Hardware
The center thermistor or an end thermistor detected a temperature
of 250°C on the hot roller.
PSU defective
IOB defective
BICU defective
SC545 A
Fusing lamp overheat error 2: Center lamp
After hot roller reaches warm-up temperature, the fusing lamps
remained on at full capacity for 11 samplings (1.8 s. duration) while
the hot roller was not rotating.
Thermistor damaged, or out of position
Fusing lamp disconnected
SC547-01 D
Zero cross signal error 1: Fusing relay
At power on and with the fusing relay off, 3 samplings detected that
the zero cross was not normal.
Fusing relay short
Fusing relay drive circuit defective
SC547-02 D
Zero cross signal error 2: Fusing relay
No zero cross signal was detected within 3 sec. after power on or
after closing the front door.
Fusing relay short
Fusing relay drive circuit defective