SC500: Feed, Transport, Duplex, and Fusing
SM Appendix 2-33 D131/D132/D133
Service Call
Conditions
SC547-03 D
Zero cross signal error 2: Unstable power supply
After 11 samplings the power supply was not within 50 to 60 Hz,
indicating that the power supply is not stable.
Check power source with local supplier
SC551 A
Fusing thermistor error 1: End thermistor
The end thermistor (contact type) was less than 0C (32F) for more
than 7 seconds.
Thermistor connector loose, broken, defective
Thermistor incorrectly installed or loose
SC552-01 A
Fusing reload temperature error 1: End thermistor
The end thermistor (contact type) could not detect:
100°C 25 seconds after the start of the warm-up cycle.
A change in temperature more than 16 degrees for 5 seconds.
The reload temperature with 56 seconds after the start of the
fusing temperature control cycle.
Fusing lamp disconnected
Thermistor connector loose, broken, defective
Thermistor out of position, installed incorrectly
Thermostat open
SC552-02 A
Fusing reload temperature error 2: End thermistor
The hot roller did not reach 100
C within the prescribed time.
Fusing lamp disconnected
Thermistor connector loose, broken, defective
Thermistor out of position, installed incorrectly
Thermostat open