SC600: Data Communication
SM Appendix 2-43 D131/D132/D133
Appendix:
Service Call
Conditions
Error Problem Solution
1 Failure to certify dial-up
In the User Tools, check the dial-up user and dial-up
password settings
4 Illegal modem setting
Check the setting of SP5816 160 to determine
whether the setting for the AT command is correct. If
this SP setting is correct, then the problem is a bug in
the software.
5
Poor connection due to low
power supply on the line.
The problem is on the external power supply line, so
there is no corrective action on the machine.
11
Data in the NVRAM
became corrupted when
the network enable switch
and Cumin-M were
enabled at the same time.
Use SP5985 1 and set the NIC to "0" (Disable) to
disable the network board.
12
The modem board could
not enable the NIB.
Replace the modem board.
SC651-01 C
Illegal Remote Service Dial-up CTL
An expected error occurred when Cumin-M dialed up the NRS Center.
Software bug
No action is required because only the count is logged