SC600: Data Communication
D131/D132/D133 2-44 SM Appendix
SC651 C Incorrect dial up connection CTL
01
- Chat program execution error
An unexpected error occurs when the modem (Cumin-M) tries to call
the center with a dial up connection.
Caused by a software bug
No action required
This SC does not interfere with operation of the machine.
SC652 D
Remote service ID2 mismatching
There was an authentication mismatch between ID2 for @Remote, the
controller board, and NVRAM.
Used controller board installed
Used NVRAM installed
An unexpected error occurs when the modem (Embedded RCG-M)
tries to call the center with a dial up connection.
Install the correct controller board or anew controller board.
Install the correct NVRAM or new NVRAM.
SC653 D
Incorrect remote service ID2 CTL
ID2 stored in the NVRAM is incorrect.
Used NVRAM installed
An unexpected error occured when the modem (Embedded
RCG-M) tries to call the center with a dial up connection
Clear the ID2 in the NVRAM
Input the correct ID2.