SC700: Peripherals
D131/D132/D133 2-48 SM Appendix
SC720-24 B
Exit guide motor (D611/D612)
The status of the exit guide sensor did not change at the
prescribed time during operation of the exit guide.
Exit guide open sensor loose, broken, defective.
Exit guide motor defective
Finisher main board defective
SC720-25
Punch motor error (D611/D612)
After the punch operation, the punch HP sensor did not detect the
punch unit at the home position.
Punch motor connection loose, broken, defective.
Punch overload (blocked by obstruction)
Home position sensor connection loose, broken, defective
HP sensor defective
SC720-30 B
Finisher jogger motor error (D611/D612)
The finisher jogger HP sensor remains de-activated for more
1,000 pulses when returning to home position.
The finisher jogger HP sensor remains activated for more than
1,000 pulses when moving away from home position.
Jogger HP sensor defective
Jogger mechanism overload
Jogger motor defective (not rotating)
Finisher main board defective
Harness disconnected or defective