Service Call
Conditions
SC720-41 D
Feed-Out Belt Motor Error (D611/D612)
The stack feed-out belt HP sensor does not activate within the
specified time after the stack feed-out belt motor turns on. The 1st
detection failure causes a jam error, and the 2nd failure causes this
SC code.
If the motor is operating
Stack feed-out HP sensor harness loose, broken, defective
Stack feed-out HP sensor defective
If the motor is not operating:
Feed-out motor blocked by an obstruction
Feed-out motor harness loose, broken, defective
Feed-out motor defective
Booklet finisher main board defective
SC720-42 B
Finisher stapler movement motor error (D611/D612)
The stapler HP sensor is not activated within the specified time
after the stapler motor turned on. The 1st detection failure issues a
jam error, and the 2nd failure issues this SC code.
Stapler movement motor disconnected, defective
Stapler movement motor overloaded due to obstruction
Stapler HP sensor disconnected, defective
SC720-43 B
Finisher corner stapler rotation motor error (D611/D612)
The stapler does not return to its home position within the specified
time after stapling. The 1st detection failure issues a jam error, and
the 2nd failure issues this SC code.
Stapler rotation motor disconnected, defective
Stapler rotation motor overloaded due to obstruction
Stapler rotation HP sensor disconnected, defective