SC900: Miscellaneous
D131/D132/D133 2-90 SM Appendix
Recovery Procedure 4
If "Recovery Procedures 1 to 3" fail to correct the problem, replace the HDD.
SC910
B
External Controller Error 1
SC911 External Controller Error 2
SC912 External Controller Error 3
SC913 External Controller Error 4
SC914 External Controller Error 5
The external controller alerted the machine about an error.
For more, refer to the instructions for the external controller.
SC915 A
External Controller Error 6
Egret board error
The external controller alerted the machine about an error.
Replace the Egret controller board.
SC919 B
External Controller Error 6 GW
While EAC (External Application Converter), the conversion module,
was operating normally, the receipt of a power line interrupt signal
from the FLUTE serial driver was detected, of BREAK signal from
the other station was detected.
Power outage at the EFI controller.
EFI controller was rebooted.
Connection to EFI controller loose.
Cycle the machine off/on