3.13.3 ADF INPUT CHECK: SP6007
1. Open SP mode SP6007.
2. Select the SP number that corresponds to the component you wish to check. (Refer to the
table below.)
3. Press On then press Off to test the selected item. You cannot exit and close this display until
you click Off to switch off the output check currently executing.
6007 ADF Input Check
Description
Reading
0 1
1 Original Length Sensor 1 (B5) No paper Paper detected
2 Original Length Sensor 2 (A4) No paper Paper detected
3 Original Length Sensor 3 (LG) No paper Paper detected
4 Original Width Sensor 1 No paper Paper detected
5 Original Width Sensor 2 No paper Paper detected
6 Original Width Sensor 3 No paper Paper detected
7 Original Width Sensor 4 No paper Paper detected
8 Original Width Sensor 5 No paper Paper detected
9 Original Set Sensor No paper Paper detected
10 Separation Sensor No paper Paper detected
11 Skew Correction Sensor No paper Paper detected
12 Interval Sensor No paper Paper detected
13 Registration Sensor No paper Paper detected
14 Exit Sensor No paper Paper detected
15 Feed Cover Sensor Open Close
16 DF Position Sensor Open Close
18 Pick-up Roller HP Sensor Not HP HP