Main SP Tables-1
System Maintenance Section 2-141 D146/D147/D148/D149/D150
009
FC Offset Amp *ENG [-300.0 to 300.0 / 0.0 / 0.1um/step]
Off set amplitude of BIT1 control
1904 [Phase Angle]
001
Trsns Bkdrum *ENG [0 to 359 / 0 / 1deg/step]
Displays phase angle of BIT1 control
002
FC Drum *ENG [0 to 359 / 0 / 1 deg/step]
Displays phase angle of BIT1 control
003
Cy *ENG [0 to 359 / 0 / 1deg/step]
Displays phase angle of BIT1 control check
004
Ma *ENG [0 to 359 / 0 / 1deg/step]
Displays phase angle of BIT1 control check
005
Ye *ENG [0 to 359 / 0 / 1deg/step]
Displays phase angle of BIT1 control check
006
Bk Offset Angle *ENG [0 to 359 / 0 / 1deg/step]
Off set angle of BIT1 control
007
FC Offset Angle *ENG [0 to 359 / 0 / 1deg/step]
Off set angle of BIT1 control
1907 [Paper Feed Timing Adj.]
029
By-pass Size Decision Timing *ENG [1 to 3 / 3 / 1/step]
Adjusts waiting time till fix a size from size detector's output when paper is set
with standard bypass or one action bypass function is OFF. Will have more time
till start button to turn green when setting waiting time longer, but time for setting
paper will also be loner. Side effect might occur such as paper feed starts before
finish setting paper if waiting time is set shot.