Main SP Tables-2-1
D146/D147/D148/D149/D150 2-176 System Maintenance Section
Sets edge detecting threshold value of Image transfer belt / TMP sensor test
mode.
The results will turn out as following in Image transfer belt / TMP sensors test
mode.
§ When TMP sensor detection value is larger than this setting value: No
problems.
§ When TMP sensor detection value is smaller than this setting value: Edge
detected.
2115 [Gamma Correction]
001
Low CPP edge Correction *ENG [0 to 100 / 80 / 1%/step]
Sets gamma correction value of valid pixel for low CPP edge process.
§ Value increase: Deeper density
§ Value decrease: thinner density
2117 [Skew Adjustment]
001
Pulse: M *ENG [-75 to 75 / 0 / 1pulse/step]
M: skew adjust: input
002
Pulse: C *ENG [-75 to 75 / 0 / 1pulse/step]
C: skew adjust: input
003
Pulse: Y *ENG [-99 to 99 / 0 / 1pulse/step]
Y: skew adjust: input
2118 [Skew Adjustment]
001
Execute: M ENG [0 or 1 / - / -]
M: skew adjust: execute
002
Execute: C ENG [0 or 1 / - / -]
C: skew adjust: execute
003
Execute: Y ENG [0 or 1 / - / -]
Y: skew adjust: execute