Main SP Tables-2-1
D146/D147/D148/D149/D150 2-178 System Maintenance Section
006
PWM: Center *ENG [0 to 1023 / 0 / 1/step]
Saves / Refreshes PWM setting value of TMP sensor [Center] to this setting
value when Vsg adjustment is done.
From then on, PWM setting value will be this setting value during belt check.
When Vsg adjust fails, saving / refreshing will not be done to this setting
007
PWM: Rear *ENG [0 to 1023 / 0 / 1/step]
Saves / Refreshes PWM setting value of TMP sensor [Rear] to this setting
value when Vsg adjustment is done.
From then on, PWM setting value will be this setting value during belt check.
When Vsg adjust fails, saving / refreshing will not be done to this setting
2141 [TM/ID Sensor Check Result]
005
Average: Front *ENG [0.00 to 5.50 / 0.00 / 0.01V/step]
Saves / Refreshes TMP sensor [Front] detecting result average data to this SP
from result of Image transfer belt / TMP sensor check mode.
006
Average: Center *ENG [0.00 to 5.50 / 0.00 / 0.01V/step]
Saves / Refreshes TMP sensor [Center] detecting result average data to this
SP from result of Image transfer belt / TMP sensor check mode.
007
Average: Rear *ENG [0.00 to 5.50 / 0.00 / 0.01V/step]
Saves / Refreshes TMP sensor [Rear] detecting result average data to this SP
from result of Image transfer belt / TMP sensor check mode.