11
2017 Page 11 5IN2413 B
Main Capabilities Description
Grade compatibility Grade 2 and 3 (selectable)
Total zones
8-512 (8 on main panel terminal block) – all zones are fully
supervised and programmable
Zone types 35
Bus zones 512
Hard wired zones 512
Wireless zones 256 (1-way & 2-way)
Partitions & groups
• 32 partitions (any zone can be associated to any partition)
• Each partition supports zone sharing and cross zoning
• Up to 4 groups per partition
RISCO bus lines
(RS485)
4 (each independent of the others). Each bus line has a
dedicated quick connector option on main panel PCB. Each
bus supports up to 32 bus devices (128 total)
Zone termination &
resistance
• Fully selectable termination resistance values.
• Five zone termination options available: normally closed
(NC), normally open (NO), end-of-line resistance(EOL),
double end-of-line resistance (DEOL), and triple-end-of-
line-resistance (TEOL)
Utility outputs 6—262, programmable (6 on main panel terminal block)
User codes
• 500 user codes, with choice of authority levels
• 1 code each for installer, sub-installer and Grand Master
Event log 2000
Wired keypads 48
Wireless keypads 32
Wireless keyfobs 256 (1-way, 2-way) including panic keyfob
Proximity key
readers
64
Bell tamper input Yes (main panel terminal block)
Box tamper input Yes (main panel terminal block)
Communication
modules
• Multi-socket IP (various models available)
• Multi-socket GSM-2G, and GSM-3G
• Single-socket GSM/GPRS
• Single-socket IP
• PSTN
• STU (UK)
• LRT (Long-range Radio Transmitter)
Audio Modules
• Voice Module
• Listen-In & Speak Unit