11
2017 Page 61 5IN2413 B
Bus Zones (Bus Detectors)
1. From the installer Programming menu, go to: 7 1 2 0 9 (Install
Bus Device Manual scroll to 09)Bus Zone), and then press OK ( ); the
first available (non-allocated) bus zone displays as per this example (the empty
fields in the parenthesis indicate that the zone has not yet been allocated):
Select (-:- -- :- -)
017) ZONE 017
2. Scroll to the zone that you want to allocate the bus zone to, then press OK; the
following (example) displays:
BUS ZONE: (017)
(1:00:01) T=xxxx)
EXPLANATION:
• 1 is the bus line number
• 00 is the bus zone expander ID (1—32) that the bus detector is connected
to (00 means wired to a bus line at the main panel PCB)
• 01 is the installer-set physical ID number for the bus detector
• T is the type (description).
3. Scroll to and then edit the bus detector’s physical ID number to match its DIP
switch settings (see Describing Installer-Set ID Numbers for Bus Devices, page 38).
4. Toggle to the correct bus zone type (or select NONE to cancel its allocation), and
then press OK; “Link Bus Input to Zone ###?” displays (whereas ### is the zone
number).
5. To link (enable), toggle to Y, and then press OK.
6. Repeat this procedure for all additional bus detectors.
Bus Zone Expanders
1. From installer Programming menu, go to: 7 1 2 1 3 (Install Bus
Device Manual Bus Expander); the 1st BZE (bus zone expander) displays
(see ID Number Formats, page 39 for a description of the displayed BZE format).
2. Scroll to, and then edit the BZE’s physical ID number to match its DIP switch
settings (see Describing Installer-Set ID Numbers for Bus Devices, page 38).
3. Toggle to the type (or select NONE to cancel its allocation), then press OK ( ).
4. Repeat from step 2 for all additional BZEs.