11
2017 Page 51 5IN2413 B
Viewing Zones, Defining Partitions, and Setting the Time & Date
You can now view enabled zones (the default of 64 zones, or the total number of
enabled zones including any additional zone licenses purchased), select the
maximum number of partitions, and set the time & date.
NOTE: You can opt to define the maximum partitions at a later stage – from the
keypad (during installer programming), or from the Configuration Software.
NOTE: To view/ update zone licenses and set partitions after system initialization,
see Viewing & Updating Zones & Defining Partitions after Initialization, page 52.
Viewing Zones, Defining Partitions and Setting Time/Date at Initialization
To view zone licenses, define partitions & set time/date at system initialization:
NOTE: If the Authorize Installer parameter is defined as YES, you need to enter the
Grand Master code (default is 1234) for authorization to enter Programming mode.
1. When prompted, enter the installer code (default is 1111) and press OK ().
Enter the code within 10 seconds or wait a few seconds for the keypad to restart;
• If the panel configuration is Cloud-compatible (IP/GSM module/s are
installed), then CLOUD CONNECTING displays as the panel tries to
connect to the Cloud. If there is trouble connecting, CONNECTION
TROUBLE. RETRY? will display – in this case, check parameters and
perform diagnostics (see Appendix J: Troubleshooting, page 230) and then
select Y (yes) to try again to reconnect or press N (no).
-OR-
• If the panel configuration is not Cloud-compatible (IP/GSM module/s are
not installed), then 064 ZONES ENABLED displays (the default number of
zones).
2. Press OK; upon successful Cloud connection, if new zone licenses (above the 64
supplied) have been purchased, they will display. If no new zone licenses were
purchased, the default 064 Zones Enabled displays.
3. Press OK; PARTITION QUAN 08 (08—32) displays.
4. Enter the maximum number of partitions you want in the system – the default is
08 (meaning up to 8); but up to 32 can be selected. If you want more than 8
partitions, enter the number. Now press OK; ENTER TIME/DATE displays.
5. Enter the time and date, and then press OK; BUS DEVICE: 1) AUTOMATIC
displays, indicating you are now in the installer Programming menu, and ready
to perform an Auto Settings scan (see Step 3: Allocating and Configuring Installed
Components, page 53).