Manually Allocating and Configuring STU Adapter
For the UK only.
Manually Allocating & Configuring other Modules and Bus
Devices
If you didn’t yet run an Auto-Setting scan to allocate (“enable”) all the installed
non-communication modules (for example, expansion modules) or other bus
devices – or if you are adding new ones and don’t want to perform an Auto-Setting
scan of the entire system, instead you can allocate them manually from the
installer’s Programming menu. Also, if you didn’t configure the parameters during
an Auto-Setting scan, you can do so now.
IMPORTANT: If no longer utilizing a previously allocated module/bus device,
you’ll need to manually cancel its allocation. After cancelling, if needed, you can
then re-write over it (to newly allocate) another module/bus device.
NOTE: To set additional parameters, see Installer Programming, page 77.
NOTE: After manually programming other modules and bus devices, you can
perform a Bus Test to ensure good communication between the bus devices and
the main panel (see Performing a Bus Test, page 54).
Wired Keypads
1. From the installer Programming menu, select 7 1 2, then scroll to
01)Keypad and press OK ().
2. Scroll to, and then edit the keypad’s physical ID number to match its DIP switch
settings (see Describing Installer-Set ID Numbers for Bus Devices, page 38).
3. Toggle to the correct keypad type (or select NONE to cancel its allocation), and
then press OK; Assign to Partition displays.
4. Scroll to manually edit (type in) the partition number or toggle to the correct
partition number, and then press OK; the Mask screen displays where you
enable operability of specific partition(s) with this keypad. By default, for
keypad 01 all partitions are enabled.
5. While scrolling through each block of partitions, designate the partition(s) to
allow operation via the keypad. Enter a partition number to select it (it will
display), or enter the number again to clear it (it will not display). Then press
OK; Controls / 1)Emergency displays.