2017 Page 150 5IN2413 B
Communication
Define the following parameters for establishing system communication:
Method
Monitoring Station
Configuration Software
Follow Me
Cloud
Reporting Priority
 Method
Define communication channel parameters for the following methods:
PSTN
GSM
IP
LRT
Communication Method PSTN
Quick keys Parameter Default Range

PSTN
The PSTN screens contain parameters for the communication of the ProSYS
Plus over the PSTN network.

Timers
Timers related to communication through the PSTN channel

PSTN Lost
4 minutes
0
20 minutes
The time after which the system will regard the PSTN line as lost. This time
also specifies the delay before reporting the event into the event log or
operating a utility output that follows this event.
00 indicates no supervision of the phone line.

Wait for Dial Tone
3
0255 seconds
The number of seconds the system waits to detect a dial tone.