2017 Page 151 5IN2413 B
Quick keys Parameter Default Range

Control

Alarm Phone Line Cut
No Yes/No
YES: Activates the external sirens if the land line, connected to the ProSYS
Plus panel is cut or the telephone service is interrupted for the time defined
in the PSTN Lost time parameter.
NO: No activation occurs.

Answering
Machine Override
Yes Yes/No
YES: The Answering Machine Override is enabled, as follows:
1. The configuration software at the alarm company calls the account.
2. The software hangs up after one ring by the CS operator.
3. Within one minute, the software calls again.
4. The ProSYS Plus is programmed to pick up this second call on the first
ring, thus bypassing any interaction with the answering machine.
Note
This feature is used to prevent interference from an answering machine with
remote configuration software operations.
NO: The answering machine override is disabled, and communication takes
place in the standard manner.

Parameters

Dial Method
DTMF
When selecting the dialing method, your choice must be compatible with the
type of phone service available at the protected premises. Scroll between the
options:
DTMF (touch-tone)
PULSE, 20BPS
PULSE, 10BPS

Rings To Answer
12
01
15
The number of rings before the system answers an incoming call

Area Code
The system area telephone code. This code will be deleted from a telephone
number while the system tries to dial the number through the PSTN
network.