Risco ProSYS Plus - Wireless Zones: 2-Way Magnetic Contact Detector (X73)

Risco ProSYS Plus
280 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11
/
2017 Page 128 5IN2413 B
Quick Keys Parameter Default Range
ZZZ
Detection Mode
2.5 Min
2.5 min/ 2.5 sec
Normal 2.5 Min Fast 2.5 Sec
If automatic detection mode is enabled, designate here the polling
periodicity of alarm generating events.
ZZZ
Sensitivity
Defines the visual sensitivity of the detector.
LOW HIGH
LOW MEDIUM HIGH MAXIMUM (WatchOUT only)
(For IR Beam) Defines the sensitivity of the detector (how long
must the beam transmission be interrupted to generate an alarm
event)
LOW 900 mSEC MEDIUM 675 mSEC
HIGH 450 mSEC MAXIMUM 225 mSEC
Wireless Zones: 2-Way Magnetic Contact Detector (X73)
Quick Keys Parameter Default Range
ZZZ
Serial No.
Normal
The identifying 11-digit number on the detector sticker
ZZZ
Control
ZZZ
Supervision
No Yes/No
Determines if this zone will be supervised by the system expander
according to the time defined under the timer RX Supervision
(see RX Supervise, page 79).
ZZZ
LED Enable
Yes Yes/No
Defines whether or not the LEDS operation mode is enabled
ZZZ
(M&F Univ only)
Magnet Enable
Yes Yes/No
Yes (Enable) or No (disable) the transmitter’s magnet.
ZZZ
Alarm Hold On
On On/Off
Use this parameter to define the minimum period between alarm
broadcasts.
ON: Only one alarm message is transmitted in any 2.5 minute time-
period
OFF: Alarm detection is immediately transmitted