11
/
2017 Page 129 5IN2413 B
ZZZ
Input Termination
N/O N/O, N/C, DEOL
Use this parameter to program the connection type used for each of
the system’s zones
(F Shutter only) Shutter: Specifies that the Input 2 will count the
number of open and close pulses received. If the zone exceeds the
predefined number of pulses, the zone will be tripped and act
according to its type definition. After a 25-second timeout, the pulse
counter is restarted. The pulse length is the currently defined Loop
Response time period.
N/O: Uses normally-open contacts and no terminating End-of-
Line Resistor
N/C: Uses normally-closed contacts and no terminating End-of-
Line Resistor.
DEOL: Uses normally-closed (NC) contacts in a zone using two
10 KΩ of End-of-Line Resistors to distinguish between alarms and
tamper conditions
ZZZ
Input Response
Time
500 10/500mSEC
10 mSEC 500mSEC
Set the duration for which a zone violation must exist in order for
the zone to trigger an alarm condition.
ZZZ
(F Univ. only)
Anti-Sabotage
Disable Enable/Disable
Enable or disable the transmitter’s anti-sabotage magnet.
ZZZ
(F SP only)
Shutter Pulse
02 01—16
Define here the number of pulses for the input.