11
2017 Page 74 5IN2413 B
Step 9: Configuring Common System Parameters
NOTE: In addition to defining these common system parameters, see Installer
Programming, page 77 for programming all other parameters in the installer
Programming menu, as well as in the other installer menus.
Defining System Users
As the installer, you must set up the user codes for all the system users (up to 500
codes total, which includes 499 users including the Grand Master, plus the installer).
Performed from a wired keypad or from the CS, you configure the code length and
the authority levels (permissions) for the system users as determined by the Grand
Master (the default authority level is User). The Grand Master will select the
numerical codes for each user from a wired keypad or the Web user interface. The
installer can also change the default installer and Grand Master codes.
NOTE: You designate the code lengths to be either 4 or 6 digits in length. If
defined as 6 digits, the length apply for everybody - all users/installers, however if
defined as 4 digits, Grand Master, Installer, and Sub-Installer must have 4-digit
codes, while the system users can codes of various lengths, from 1—4 digits.
Defining User Codes
To define user codes:
1. From installer Programming menu go to: 4)Codes1)User then press OK ().
2. Scroll to a user’s index number (1—500 users possible), then press OK; the user
number and “1) Partition” display.
3. Press OK. To assign partition(s) this user will be allowed to operate, do the
following:
a. While scrolling through each increment of 10 partitions, select partition(s)
to allow operation by this user. Enter a partition number to select it (it will
display), or enter the number again to clear it (it will not display).
b. When finished selecting all partition numbers press OK.
4. To assign an authority level for this user, do the following:
a. After assigning partitions (step 3), scroll to 2)Authority, then press OK.
b. Press to scroll to the authority level for this user (User, Arm Only,
Maid, Unbypass, Guard, Duress, UO Control, Master), then press OK.
NOTE: "Duress" is not an authority level, but a feature available to all users. By
selecting this option (use any available user index number) the Grand Master will
then assign a code that all users can use in times of duress, where they are forced to
disarm the system. The monitoring station is sent an alarm, but the panel is silent.