11
2017 Page 60 5IN2413 B
4. While scrolling through each block of partitions, designate the partition(s) to
allow operation via the PKR. Enter a partition number to select it (it will
display), or enter the number again to clear it (will not display), then press OK.
5. Scroll through the various “Controls” options and toggle between Y and N for
each, and then press OK.
6. Repeat this procedure from step 2 for all additional PKRs.
Voice Module
1. From the installer Programming menu, select 712, scroll to
07)Voice Module, and then press OK ( ).
2. Toggle to T=Voice (the Voice Module), or select NONE to cancel its allocation),
and then press OK.
3. Enter the 2-digit R. Phone Code (remote phone code), and then press OK.
4. Scroll to select a language for voice announcements, and then press OK.
Sounders (Sirens)
1. From the installer Programming menu, select 7 1 2, scroll to 08)Sounder,
and then press OK ().
2. Scroll to, and then edit the sounder’s physical ID number to match its DIP
switch settings (see Describing Installer-Set ID Numbers for Bus Devices, page 38).
3. Toggle to the type (or select NONE to cancel its allocation), and then press OK.
4. Select the partition number(s) for the sounder. While scrolling through each
block of partitions, designate the partition(s) to allow operation via the keypad.
Enter a partition number to select it (it will display), or enter the number again
to clear it (it will not display).
5. Scroll to and select the partition number for the siren, and then press OK.
6. Select Y to enable the sound (or toggle to N), and then press OK.
7. Select Y or N for squawk sound, and then press OK.
8. Select Y or N for squawk strobe, and then press OK.
9. Repeat from step 2 for all additional sirens.