EasyManua.ls Logo

Risco ProSYS Plus - Configuration SW

Risco ProSYS Plus
280 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11
/
2017 Page 178 5IN2413 B
 Configuration SW
Configure the following parameters for communication between the Configuration
Software and the system:
Security
Call Back Phones
Controls
Gateway
Modem Protocol
Communication Configuration SW Security
Quick Keys Parameter Default Range

Security
Enables you to set parameters for remote communication between the
technician and the system using the Configuration Software

Access Code
5678
Enables you to define an up-to six-alpha-numeric-character installation access
code.
In order to enable communication between the alarm company and the
system the same access code must subsequently be entered into the
corresponding account profile created for the installation in the
Configuration Software.
For successful communication, the access code along with the ID code must
match between the Configuration Software and the system.

Remote ID
0001
Defines an ID code that serves as an extension of the access code.
In order to enable communication between the alarm company and the
installation, the same remote ID code must be entered into the account
profile in the Configuration Software.
For successful communication, the ID code along with the access code must
match between the Configuration Software and the main panel.
Dealers often use the customer’s monitoring station account number for the
ID code, but you can use any 4-digit code unique to the installation.

MS Lock
000000
MS Lock is a security function used in conjunction with the Configuration
Software. It provides greater proprietary security when viewing monitoring
station parameters.

Table of Contents

Other manuals for Risco ProSYS Plus

Related product manuals