11
2017 Page 148 5IN2413 B
Quick keys Parameter Default Range
• Maid: The maid code is a temporary code, which is automatically and
immediately deleted from the system as soon as it is used to arm. This
code is typically used for maids, home attendants, and repairmen
who must enter the premises before the owner(s) arrive. These codes
are used as follows:
o For one-time arming in one or more partitions.
o If first used to disarm the system, the Maid code may be used
once for subsequent arming.
o After deleted, the code will need to be redefined by the Grand
Master for the next usage.
o Cannot change own code
• Unbypass: This user has access to all the user’s privileges apart from
bypassing zones.
• Guard: This user can only disarm the system. After entering the
Guard code, the system will be disarmed for the predefined time
period (See: Guard Delay page 80).
• Duress: When forced to disarm the system (under duress), the system
sends a duress alarm to the monitoring station, but the panel is silent.
The duress code can be used by all system users, regardless of
authority level.
• UO Control:.
o Used to only operate Utility Output(s)
o Cannot change own code
Grand Master
Codes Grand Master
Default = 1234. The Grand Master code is used by the system-responsible (for
example, the owner), and has the highest authority level. The Grand Master can
change the Grand Master code (in the User menu).
Notes
• The Grand Master is index number 00.
• The Grand Master, the installer and the sub-installer can enter and change their codes,
but the new codes entered don’t display at the keypad – instead **** displays .