11
2017 Page 242 5IN2413 B
Appendix H: EN50131 & EN50136 Compliance
Compliance Statement
Hereby, RISCO Group declares that the ProSYS Plus series of central units and
accessories are designed to comply with:
EN50131-1, EN50131-3 Grade 3
EN50130-5 Environmental class II
EN50131-6 Type A
UK: BS 8243:2010, PD 6662:2010, ACPO (Police)
EN50136-1, EN50136-2 and EN50131-10
ATS6 for IP/GPRS; ATS 2 for PSTN
ATS EN50136-1 Category C (PSTN, GSM, IP transmission paths in parallel)
Signaling security:
• Substitution security S2
• Information security I3
EN50136 Compliance
• PSTN, IP and GSM modules are complying with the following standards:
EN50136-1:2012
EN50136-1-2:2013
EN50131-10:2014
• PSTN can be connected to a monitoring station via any EN50136
compliant receiver, which shall meet all requirements of securing
messages.
• When IP and/or GSM modules are in use, IP Receiver software is also in
use. The IP Receiver should be connected to automation software, which
serves as the EN50136 annunciator. If connection between the IP Receiver
and the automation software is lost, an error message will appear on the
IP Receiver queue.
• In order to have an indication of ACK received from the receiving center
transceiver, the parameter Kiss-Off Y/N (see page 168) should be set to Y.