Maintenance Menu
Maintenance parameters
Walk Test Test and evaluate the operation of selected zones in the system. A walk test is
set for up to 60 minutes. During the last 5 minutes, the keypad used to activate the test will
indicate that the test is about to end.
Full Walk Test (areas activated) – Displays the activated zones and type of detector
Quick Walk Test (areas not activated – Displays the non-activated zones.
Keypad Test Activates the keypads and momentarily tests the keypad indicators.
Siren Test Activates the alarm sound from each bus sounder, from the Bell terminals on
the main board and activates utility outputs defined as Bell Trigger
( ).
Strobe Test Activates all strobes in connected bus sounders and activates utility output
defined as Follow Strobe
( ).
Wireless Test – For all allocated keyfobs, wireless zones, and wireless keypads:
Comm.Test Displays the last measurement taken at the last transmission (last detection
or last supervision signal) of the selected device. To receive the updated signal strength,
activate the detector prior to performing the communication test. For successful
communication, the strength of the signal should be higher than the noise threshold level
as measured during calibration of the panel (see Performing a Wireless Comm. Test for
Measuring Signal Strength, page 70).
Battery Test Displays the last battery test results of the selected device taken at the last
transmission. A confirmation message displays if the test was successful. In addition, you
can activate the device.
Diagnostics
You can activate the following tests for system diagnosis:
Main Battery Test – Tests the level of the main panel's backup battery. Press OK to
start the test; the result displays.
Zone Resistance – Tests the resistance and voltage level of the wired zones in the
system. Press OK and then scroll to the zone to be tested. Press OK to toggle
between viewing the resistance and voltage for the selected zone. Scroll to other
zones to test as needed.
Zone Expander – Tests installed zone expanders. Press OK, scroll to the zone expander
to test, and then press OK again. Now scroll to either view the results for
DIAGNOSTICS or VERSION, and press OK; the corresponding information displays
Power supply – Tests the installed power supplied expanders and displays the
relevant information for each power supply.
Siren – Tests installed bus sirens and displays information regarding each siren
(depending on siren type). Press OK, scroll to the siren to test, and then press OK
again. Now scroll to either view the results for DIAGNOSTICS or VERSION, and
press OK; the corresponding information displays.
GSM module – Tests the following for the installed GSM module: