Audio
The following Audio menus are used to define voice message parameters:
• Messages
• Local Announcements
Note
This menu will be displayed only if a Voice module had been assigned to the system
Messages
Audio Messages
Quick Keys Parameter Default Range
Messages
Use this menu to customize the spoken messages of Zones, Partitions,
Outputs, Macro's and Opening Message that the Voice module announces
when you access the system from a remote telephone or you hear on the
premises. There are 2 ways to customize a voice message:
1. User recorded: The
Common Message and the Library Messages
are user recorded messages. The recording can be done either from the
microphone located on the voice module expander or from a microphone
located on the Listen-In & Speak unit.
Note
The definition of which microphone to use is determined by dip switch 4
located on the voice module board.
2. Assign messages: The Zone / Partition/ Output and Macro messages can
be assigned with pre-recorded messages. Each message can be comprised
of up to 4 words. Each word has been pre-recorded and assigned a
number. When comprising a message the installer will enter the number
of each word into the message sequence. The system recognizes the
numbers and sounds the words assigned to those numbers. For example:
For the system to sound “Top Floor Guest Bedroom”, you should enter
the following sequence: 119 050 061 019. The table in Appendix E:
3. Library Voice Messages, page 234 displays the directory of the pre-recorded
programming descriptors, each is identified by a 3 digit number.
Note
The first five descriptors allow for customized words specific for the client’s
needs. The customized words are the Library message on option
After recording or assigning a message you can verify messages by selecting
[1] Play option in each category.