11
/
2017 Page 99 5IN2413 B
System Sounds Wireless Lost Sound
Quick keys Parameter Default Range

Wireless Lost Sound
Sets the behavior of the sound when a wireless loss zone is detected. The
sound can be activated as in a fault condition or as in a tamper condition.
As trouble
As tamper
Determines the internal sounder volume during an alarm
 Settings
Set the System Settings parameters as needed.
System Settings
Quick keys Parameter Default Range

DIP 2 Enable/Disable
Enable Enable/Disable
Used to determine whether the ProSYS Plus default DIP switch SW1-2 is
enabled (ON position) or disabled (OFF position).
Enabled: When power to the main panel is switched off and then on and
SW1-2 is in ON position, the installer, sub-installer and Grand-Master codes
will return to the original, factory default values. In this case, after entering
the Installer Programming section, the system automatically is at the Auto
Setting scan for bus devices.
Toggle to enable/disable the option.

Default Panel
Restores programming options to factory defaults.

Erase Wireless
Erases wireless devices without changing the system current programmed
parameters. Select the wireless device to be erased.
Note
This entry appears only if a wireless device is allocated in the system.