 Alarm Confirm
The Alarm Confirm sub-menu enables you to define the following that can be used
for alarm verification:
Confirm Partition
Confirm Zones
Zones Alarm Confirm Confirm Partition
Quick keys Parameter Default Range

Confirm partition
Defines which partitions are to be defined for alarm sequential
confirmation (relevant for intrusion alarms, not HU Confirmation alarms).
Each confirmed partition has a separate timer (time period), which is
equivalent to the confirmation time defined in “Confirmation Time
Window” (see Confirm Time , page 172).
A confirmed intrusion alarm will be reported to the monitoring station if
two separate alarm conditions are detected in the same confirmed
partition, during the period of the confirmation time window.
Cycle through the partitions and toggle to Y/N for each.
Zones Alarm Confirm Confirm Zones
Quick keys Parameter Default Range

Confirm zones
Define which zones are to be defined for alarm sequential confirmation
(relevant for intrusion alarms, not HU Confirmation alarms).
When the first zone goes into alarm the system transmits the first zone
alarm. When the second zone goes into alarm, during the confirmation
time, the panel transmits the zone alarm and the police code.
Notes
A confirmed zone will be part of the sequential confirmation only if the
partition in which the alarm occurs is defined as confirmed partition as
well.
Any code can reset a confirmed alarm.
If the first zone is violated and not restored until the end of the
confirmation time (no second zone alarm), than this zone will be
excluded from the confirmation process until the next arming.
Cycle through the zones and toggle to Y/N for each.